Analysis on Performance Test Methods of Particle Cleaning Capacity for Large-scale Air Cleaners including Air Conditioners
․ ѹ* ․ ․ ․ ȿ
Abstracts
As indoor air cleaners have large sizes and high air flow rates, the test methods for particle cleaning capacity need to be reconsidered because the prescribed test chamber size becomes relatively smaller. In this study, air flow rate of air cleaners compared to test chamber size (Q/V) has been investigated by comparing the short-circuit factor which indicates the air mixed condition in the test chamber. The test method of Korea Air Cleaning Association (KACA) has been analysed and compared to that of Association of Home Appliance Manufacturers (AHAM) for clean air delivery rate (CADR) of two household air conditioners equipped with air cleaners having a maximum air flow rate of 15 m3/min in terms of initial particle concentrations, neutralized/non-charged particles, delay time before acquiring initial particle concentration, sampling positions. Constant short-circuit factor of about 0.9 was obtained in the range of Q/V less than 0.73 min-1. CADR based on KACA test method was somewhat dependent on initial particle concentrations, delay time before acquiring initial concentration, sampling positions. However, CADR based on AHAM test method was less dependent. Two or three minutes of delay time before acquiring initial concentration was necessary to reduce the variation of CADR according to initial particle concentration and sampling position.
Keywords : air cleaner, particle cleaning capacity, clean air delivery rate (CADR), test chamber