Reliability evaluation of odor sensor
1*ȫ11迵ȯ231̵1ȫ1
Abstracts
In this study, a correlation analysis of odor was performed in order to assess the reliability and the field applicability
of the Odorous gas sensor for continuous real-time monitoring. Hydrogen sulfide was found to have a correlation
of 41.5~65.8%, and Ammonia is was found to have very low correlation in less than 200 ppb concentration.
Reactivity evaluation result, hydrogen sulfide is the reactivity was higher than the low concentration condition of
100 ppb or less indicated by 31.3~36.4% in the 100 ppb or more high density condition based on the reference
density value. For ammonia was very low reactivity in the low-concentration conditions below 200 ppb. TVOC
and composite odor assessment did not occur Reactivity no reference concentration value, the specific comparison
between both sensors showed a similar trend. In the same Odorous gas sensor accuracy between the result,
40.3~130.6% hydrogen sulfide, ammonia, 69.1~104.9%, TVOCs is 24.7~98.6%, exhibited human odor intensity
from 5.5~33.2%.
Keywords : Odorous gas sensor, Human odor intensity, Hydrogen sulfide, Ammonia, TVOC