Reduction of malodor and VOCs emission through vapor recovery system
in gas station
1¿1۰ǹ12ֿ2*3
Abstracts
This study was carried out to investigate the effect of malodor and VOCs reduction that could be achieved through
the installation of a vapor recovery system (VRS) in a gas station. It was revealed that the reduction efficiencies
of malodor by running VRS were about 93% around the oil feeder, 32% in the office and 45% in the site boundary.
Specifically, it was remarkable that reduction efficiencies of BTEX over 90% were recorded through VRS
operation. In addition, the results of continuous monitoring of THC around the oil feeder device provided good
evidence of the inhibition of oil mist diffusion after running VRS.
Keywords : BTEX, Malodor, Vapor Recovery System (VRS), VOCs