dzȯ ȸ
15 1ȣ, March 2016
|
ISSN : 2288-9167 (Print)
ISSN : 2288-923X (Online)
|
Flow and particle transport analysis near the electrostatic precipitator
in metro tunnels
1缺1ڴ23Ǽ2*¼1,3*
Abstracts
In this study, we numerically analyzed flow and particle transport near the electrostatic precipitator in the tunnel
according to train runs. When there was no train running, flow field was formed by a precipitator. Flow emitted
from precipitator blocks the path along the tunnel, and therefore most contaminated air passes through the
precipitator and can be cleaned. On the other hand, flow pattern during the train run was affected by train induced
wind. A strong straight flow was generated at the front of train, and back flow was formed in the opposite line.
When a train runs upward only (train start from suction section to blow section), the subway train transports
contaminated particles along the tunnel. For downward train runs only case, the cleaned air reentered the
contaminated section with train wind. Both train runs case showed combined flow and particle concentration
pattern of both single train runs.
Keywords : CFD (computational fluid dynamics), Particle concentration, Subway tunnel, Train run