dzȯ ȸ
15 2ȣ, June 2016
|
ISSN : 2288-9167 (Print)
ISSN : 2288-923X (Online)
|
A study on the health effect to determine an H2S emission standard for incinerators
*
Abstracts
This paper presents the results of a human health effect for H2S emission standard of incinerators in Seoul, Korea. The four selected incinerators of Gangnam, Mapo, Nowon and Yangcheon were chosen as the domains of study. Air dispersion modelling (AERMOD) was used to predict the ground level concentration within 3 km distance of the emission source. The emissions at the incinerators studied ranged from 0.0721 (Yangcheon) to 0.3007 g/s (Gangnam). These values were about three orders of magnitude smaller than that of Canadian geothermal power plants. Based on the health risk assessment, different health risks were identified for short-term and long-term dispersion of the studied areas. The short-term hazard quotient (HQ) for H2S of Gangnam and Nowon incinerators were greater than the acceptable limit (i.e., 1.0) in some locations. However the long-term HQ for H2S of all incinerators were lower than the acceptable limit.
Keywords : Aermod model, H2S, Hazard quotient, Health risk assessment, Incinerator