dzȯ ȸ
15 4ȣ, December 2016
|
ISSN : 2288-9167 (Print)
ISSN : 2288-923X (Online)
|
A study on odor removal efficiency of wastewater treatment plant by multiple process
ö1̽2̿3ǿ1*
Abstracts
The purpose of this study is to investigate and compare the change of wind velocity and processing efficiency of sulfuric compounds and more complex odors. The research was conducted in a facility specializing in odor prevention applications using upgraded existing research equipment (from 30 CMM to 200 CMM) on wastewater treatment. The research equipment was installed with the purpose of removing odor from the wastewater treatment (Pasteur Factory) located in Hoengseong-gun, GangWon. To investigate the treatment efficiency of hydrogen sulfide test samples were evaluated with different blower installation positions and changes in wind speed. The wind speed at the static pressure is about 1.70~2.08 times faster than that of the static pressure, although the blower power is different. The efficacy of sulfur compounds and complex odor treatment was 91.27% and 95.20%, respectively. The study results show that it is necessary to review the design point of wind speed due to the increase in facility scale. In addition, considering the characteristics of complex odor, it is necessary to consider additional surcharges. It was determined that the facility plan for odor prevention in relation to wind velocity will be reexamined. Ongoing research will also be considered to help identify any disadvantages and solutions for the ventilator positioning, which is currently installed in the back.
Keywords : Complex odor, Facility design, Multiple process, Sulfur compounds, Wind speed