Weekly variation of indoor air quality in a nursing room of a day-care center near the roadside
1̽º1翵2̱13ȯ4ͳ1*
Abstracts
The number of children who use day-care centers is increasing. Most indoor air quality (IAQ) management has been based on daily average pollutant concentrations measured once a year. A more comprehensive management of IAQ is needed to protect childrens health from air pollutants in day-care centers. In this study, we investigated the weekly variation of air pollutant concentrations in a nursing room of a day-care center located at the roadside for a week in June of 2014. Average concentrations of CO2, PM10, black carbon, and total surface area of lungdeposited particles during nursing time of the day-care center were 510 ppm, 27.8 µg/m3, 1.87 µg/m3, and 30.6 µm2/cm3, respectively, with a similar diurnal pattern shown on weekdays.
Keywords: Children, CO2, Day-care center, Indoor air quality, PM10