A Survey on the Indoor Air Quality of Some School Classroom in Gyeongbuk area
Ȼ*,,,̿,ä,,
Abstracts
This study was performed to investigate the characteristics of indoor air quality (IAQ) in elementary and middle schools in Gyeongbuk area from July to November 2006 . The measurements of indoor air pollutants were made to cover such components as PM-10, CO2, CO, NO2, O3, HCHO, TVOC, TBC, and Radon from school classrooms. The results of this study can be summarized as follows: all of them were less than IAQ
standards of Korea. The mean concentration were measured by 43.0 / (PM-10), 745 ppm (CO2), 56.1 /
(HCHO), 350 CFU/ (TBC), 0.026 ppm (O3), 0.6 ppm (CO), and 59.2 / (TVOC). Radon was not detected in all surveyed classrooms. The I/O ratio of PM-10 was 0.81.4, while that for HCHO was 5.79.0. Therefore, it was concluded that the indoor pollution of formaldehyde was very serious in classroom.
KeywordsNew school, Indoor air quality (IAQ), Indoor air pollution (IAP), I/O ratio.