A Study on the Concentration Levels of VOCs at the Underground Parking Lots in Daejeon
ϴȣ, , ̺, , 輱*
Abstracts
In this study, VOCs originating from vehicles were measured at 8 underground parking lots(two apartments, four department stores, and two large-scale marts) in Daejeon. The indoor air quality at underground parking lots of the department stores and marts was affected by the availability of the ventilation facility and their operation frequency. At the underground parking lots with a ventilation facility, the maximum VOCs concentration was 727/, and the minimum was 73.5/. The average concentration ratio of BTEX to TVOCs at the underground parking lots was almost constant, which was approximately 44.8%. TVOCs and BTEX were strongly correlated with a correlation coefficient (r) of 0.88. The relative ratio of benzene, toluene, ethylbenzene and xylene was 1 : 9.51 : 0.71 : 2.53, directly reflecting the influence of vehicles sources.
Keywords : VOCs, underground parking lot, air quality, GC/MS